Special Features of MAYA FRP Cooling Towers 
·Motor IP-55 especially insulated for cooling tower duty.

·High efficiency Aerodynamic well balanced adjustable pitch bladed Fan specially design for cooling tower application.

·FRP fan deck.

·
MAYA cooling tower use PVC Water Distribution System which give easy installation and long life.

·Well design Polypropylene nozzles easy maintenance and reduced clogging there for cooling tower performance dose not reduce over a period of time.

·Thermoformed PVC film fills at low air rates.

·Drift Eliminators limit drift losses to no more than .005% of the cooling tower design flow rate.

·Field assembled simplifies transportation to job-site.

·FRP Inspection window which help for easy monitoring and maintenance of cooling tower.

·With our efficient design and energy saving MAYA cooling tower fan our cooling tower operation and maintenance cost is comparatively low.

Main Features of Cooling Towers












































MAYA Cooling Tower Range -

Maya FRP cooling tower rage is from 40 - 600 in single shell.

Cooling Tower components is as below:

Long Life Construction
: The body of the cooling tower is manufactured and assembled from corrosion-resistant composite Fiberglass and MS HDG construction meet the
excellent structural strength. Heavy-duty construction, high-performance design, and our five-year mechanical warranty ensure consistent, fully rated cooling over wide range of flow and meet temperature requirements.

Film Fill:
The heat and mass transfer surfaces are Film type and are selected as per technical specifications however fill height is optimized to meet the design duty condition of cooling tower. High efficiency cross - corrugated textured fill is proposed. Fill shall be supported on Steel Structure.

Distribution System: Each cell features low pressure gravity down spray system. There is a main header of PVC with lateral distribution tubes and well designed injection molded polypropylene spray nozzles complete with diffuser rings. The nozzles are to open & clean incase of any foreign object introduces into the circulating water. A flange connection is located outside the sidewall column centerline above the fill for connection to buyer supplied riser. Entire distribution is designed to give uniform water spray over the entire fill plan area. 

Drift Eliminators: PVC wave type drift eliminators are proposed. Drift eliminators shall be supported on MS HDG structure.
These drift eliminators are light weight and can be easily removed as well as can be easily cleaned and maintained. Efficiency of these drift eliminators is 99.95%.

Axial Fan: Direct driven energy efficient power saving FRP bladed axial flow fan of suitable diameter as per the technical specifications. Fan blades pitch can be manually adjusted in order to meet variable duty conditions. Due care has been taken while choosing the fan with highest efficiency and lowest noise levels. Fan blades are fitted to dynamically balanced MS HDG hub. Fan assembly shall be statically balanced for interrupted performance.

Electric Motor: A.C. Squirrel cage motor with IP 55 enclosure, weather proof specially designed for cooling tower application is as per the best engineered performance selections.

Structure, Stack and Casing: Casing & Stack shall be in FRP construction. Structure shall be in FRP/MS as per suitable site/design condition.

SERVICE
We commence cooling tower service contracts for maintenance/repairs too.





image mayafan logo
Maya Fan Air Engineering Pvt. Ltd.
An ISO  9001:2008 Certified company
mayafan punch line
Save                   energy                   today                   for                   tomorrow

>>
Click here to send enquiry for maya cooling tower fans
>>
Calculation & Conversion Hub
Maya Cooling Tower Highlights : -

     Ø  30+7% less operation cost.
     Ø  Most efficient hyperbolic shape.
     Ø  Minimum air turbulence throughout the cooling tower.
     Ø  Maya high energy efficient cooling tower fans.
     Ø  Higher fan diameter there for less air velocity.
     Ø  Low RPM there for less vibration.
     Ø  Minimum air velocity to further reduce the turbulence.
     Ø  Velocity recovery cone.
     Ø  Minimum use of metal there for maximum corrosion resistance.
     Ø  Less drift loss because of less air velocity.
     Ø  Easy installation commissioning and less maintenance.
     Ø  Less operating noise because of less air velocity.

>>>Contact Us<<<
Send E-mail